An open Sonation sound insulation hood. Next to it a pump on an oil pan. In addition, various Sonation sound insulation hoods lined up.

Model SSH11

The SSH11 model is ideal for small and medium sized vacuum pumps up to approximately 230x250x600mm (WxHxD) such as the Edwards E2M30 or the Varian DS602. If oil mist filters or similar accessories are used with the pumps, the pump flanges can be extended so that the accessories can be operated outside the sound protection hood.

Configuration

Active Pump Protection System (APPS)

The APPS (Active Pump Protection System) module (Active Pump Protection System) enables you to perfectly protect your sensitive and important devices by monitoring all important operating data.
The system constantly monitors all important operating data such as temperature, current consumption and the function of the fans. In the event of a fault, an optical and acoustic warning is issued. The ventilation is temperature controlled, so that the insulated device is optimally cooled at all times.

Benefits

Sound protection
The noise level in the laboratory is significantly reduced which prevents hearing damage and leads to higher concentration and productivity.
Universal and flexible
By using pump-specific interchangeable covers, the sound protection hood fits perfectly to the pump used. If a different pump is to be insulated at a later date, this is easily possible by replacing the cover.
Simple commissioning
Commissioning of the sound protection hood can be carried out by the end user within a few minutes.
Easy pump access
Both the cover and the front can be removed with a flick of the wrist via quick-release fasteners. This makes it easy to check the oil level, operate the gas ballast valve or perform other work on the pump at any time.
Internal pump socket
All sound protection hoods are equipped with an internal socket for connecting the vacuum pump. This means that only one socket or cable is required to supply power to the pump and the sound protection hood. Separate power supply of the pump and the sound protection hood is also possible.
Temperature monitoring with alarm function - models with APPS (Active Pump Protection System)
The exhaust air temperature is continuously monitored. In the event of overheating, a visual and acoustic alarm is triggered.
Temperature-controlled fans - models with APPS (Active Pump Protection System)
The speed of the fans is controlled depending on the required cooling capacity, which contributes to an increased service life as well as optimal noise minimization.
Wide range input - models with  APPS (Active Pump Protection System)
The sound protection hood can be operated on 110V networks as well as on 230V networks.
Emergency shutdown function - models with APPS (Active Pump Protection System)
When a critical internal temperature is reached, it is possible to automatically switch off the internal socket to prevent a defect.

Technical data

External dimensions
350 x 300 x 750mm (WxHxD)
Maximum internal dimensions
250 x 275 x 675mm (WxHxD)
Noise reduction
About 16dB(A) -> Corresponds to about 80% noise reduction
Fan
Two fans for heat dissipation
Insulation material
Hochwertige Dämmung aus umweltfreundlichem Recyclingmaterial. Akustikschaum auf PUR-Basis mit vlieskaschierter, öl- und wasserabweisender Oberfläche. Entflammbarkeit: Erfüllt FMVSS 302 bzw. DIN 75200
Permissible ambient conditions Transport
Temperature: -20 - 60°C / -4 - 140°F / Humidity: 5 - 90% (non-condensing)
Permissible ambient conditions Storage
Temperature: 10 - 40°C / 50 - 104°F / Humidity: 10 - 80% (non-condensing)
Permissible ambient conditions Operation
Temperature: 10 - 30°C / 50 - 86°F / Humidity: 10 - 80% (non-condensing)

Downloads

Noise reduction boxes for backing pumps - Users manual
PDF (0.67 MB)
Flyer Noise reduction boxes
PDF (0.71 MB)
powered by webEdition CMS